Heating flange

Character

This device is used for electric heating of hot utility water designed for fitting into the flanged hole of OKCE 100–300 S and OKC 100–300NTR(NTRR)/BP water heaters. The heating unit is equipped with ceramic heating elements and operating and safety thermostat with the hot utility water temperature regulation range 5–74 °C. Heating flange TPK 210/12 can also be used in storage tanks with flange, thus NAD v1, NAD v3-v5 a NADO v1-v3.

Řez topnou přírubou
By using the adaptor flange 225/210 the user may use flanged built-in electric heating units of the following types: TPK 210/12 for OKCE S and OKC NTR(NTRR)/BP heaters with volumes between 750 and 1000 l.

 


Technical data

TypeTPK 150-8/1,5 kWTPK 150-8/2,2 kWTPK 168–8/2,2kWTPK 210–12/2,2kW
Output [kW] 1,5 2,2 2,2 2,2
Supply 1/N/PE ~ 230V/50Hz 1/N/PE ~ 230V/50Hz 1/N/PE ~ 230V/50Hz 1/N/PE ~ 230V/50Hz
Heating element lenght [mm] 400 400 400 440
Electric protection category IP42 IP42 IP42 IP42
Weight [kg] 4,2 4,2 4,2 6,6
Scale of set temperature [°C] 10 16 16 16

 

TypeTPK 210–12/3–6kWTPK 210-12/6,6 kWTPK 210–12/5–9kWTPK 210-12/8-12kW
Output [kW] 3–4–6 6,6 5-7-9 8-10-12
Supply

1/N/PE ~ 230V/50Hz

 

3/N/PE ~ 400V/50Hz

1/N/PE ~ 230V/50Hz

 

3/N/PE ~ 400V/50Hz

3/N/PE ~ 400V/50Hz 3/N/PE ~ 400V/50Hz
Heating element lenght [mm] 440 440 550 550
Electric protection category IP42 IP42 IP42 IP42
Weight [kg] 12 13 13,6 14
Scale of set temperature [°C] 20 / 3 x 16* 20 / 3 x 16*  3 x 20 3 x 25

* – according to connection method

Photogallery

TPK 210-12/3-6kW

Please visit new website www.dzd.cz/en »